Copper-Tuff Flashing
Testing Report
| Spec. Ref. | Test | Units | C-TUFF | TYPICAL FABRIC FLASHING |
|||||
|---|---|---|---|---|---|---|---|---|---|
| 2 oz. | 3 oz. | 5 oz. | 3 oz. | 5 oz. | |||||
| ASTM D412C | Tensile Strength | psi | 137,000 | 59,000 | 33,700 | 44,300 | 36,300 | ||
| Elongation | % | 3 | 2 | 4 | 2 | 2 | |||
| ASTMD1004 | Graves Tear | ||||||||
| MD | lbf. | 23.3 | 34.7 | 38.1 | 28.4 | 48 | |||
| in.@ max. load | 0.05 | 0.05 | 0.04 | 0.06 | 0.06 | ||||
| TD | lbf. | 41.1 | 38.0 | 40.1 | 26.7 | 47.2 | |||
| in.@ max. load | 0.05 | 0.05 | 0.05 | 0.05 | 0.06 | ||||
| ASTM D1938 | Tear Propagation (Trouser Tear) | ||||||||
| MD | lbf. | 4.3 | 2.5 | 5.4 | 3.1 | 4.6 | |||
| TD | lbf. | 5.2 | 5.0 | 6.2 | 5.2 | 8.6 | |||
| ASTM E154 | Puncture Resistance | ||||||||
| max. load | Ibf. | ||||||||
| deflection at max. load | in. | ||||||||
| failure type | rupture | rupture | rupture | rupture | rupture | ||||