Copper-Flex Flashing

Testing Report

  Spec. Ref. Test  Units
  ASTM D412C Tensile Strength psi 67,000  
    Elongation % 15  
  ASTMD1004 Graves Tear      
    MD  lbf. 27.4  
      in.@ max. load 0.22  
    TD lbf.  22.4  
       in.@ max. load 0.28  
  ASTM D1938 Tear Propagation (Trouser Tear)      
    MD lbf. 8.3  
    TD lbf. 9.3  
  ASTM E154 Puncture Resistance      
    max. load Ibf. 265   
    deflection at max. load in. 1.01  
    failure type    rupture